![]() | | | | Ultrasonic Nebulizers, Alternating Pressure Mattress, Patient Monitor, Fetal Monitor, Ultrasonic Instruments, Suction Machine, ECG Machine, Wheel Chairs, Nursing Bed Series, Walker and Waking Aids, Comprehensive Nursing Series, Shadowless Operation Lamp, Oxygen Intake Device, Operating Table, Pulse Oximeter, | ![]() | | | | X-RAY Illuminator, X-ray Film Cassettes, Intensifying Screen, Dark Room Accessories, Developing Film Hanger, X-ray Film Processor, Medical X-RAY Machine, Medical X-RAY Camera, X-RAY Protective Accessories, X-ray Film Processing Machine, Sensitive X-ray Film, | ![]() | | | | | ![]() | | | | | ![]() | | | | Disposable Syringe, Disposable Infusion Set, Disposable Tubings, Disposable Hypodermic Needle, Disposable Gloves, Extracorporeal Circuit, Enaesthesia Use, Blood Collection Tube, Gynecology Products, Urological Products, Safety Condom, | ![]() | | | | | ![]() | | | | Cotton Products, Elastic Bandage, First Aid Bag, First Aid Plasters, Gauze Products, Orthopaedic Bandage, Wound Care Plaster, Surgical Tapes, Transparent Island Dressing, Transparent Semi-permeable Dressing, Surgical Film, Non-woven Adhesive Wound Dressing, | ![]() | | | | | ![]() | | | | | ![]() | | | | |
|
|
|
| |  | | Name:MST-KT150 150mA Medical X-ray Machine |
|
|
| |

| Name:MST-KT150 150mA Medical X-ray Machine | | Code:MST1072353 | | PRODUCTS INTRODUCTION: | |
USE:Roentgenoscopy Digestive track spot film photograpy General photograpy Filter-ray device photograpy
MAIN CHARACTERISTICS :
1.Single bed and single bulb.
2.Design according to the electric mechanism of middle-size machine.The function is full and reasonable.
3.The high-tension system is of march-past structure.Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit,with large output power and reliable and stable operation.
4.Supply voltage V,roentgenoscopy,photograpy KV and stepless adjustable.
5.Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output.
6.Equipped with the capacity limitation and protection circuit and KvmA sinterlock limitation and protection.
7.Adopt the digital circuit timer,grade according to R10 prioritycoefficient and can control time exactly
8.Examining bed is of electirc back rotation and is equipped with vibrating filter-ray device.
9.The spot film device of luminescent screen can hold the film jacket of various sizes and can make the photograpy of full-film and twosectional films separately
10.The upright post doesn't have the top-track ,which is easy whileinstallation
TECHNICAL PARAMETER
| ITEM |
CONTENT |
INDEX |
| Upright post |
move lengthwise (along the bottom track) |
1500mm |
| move transverse |
360mm |
| move up and down (along upright post) |
720~1720mm(from focus to ground) |
| Supply power |
voltage |
单相 380V/220V |
| frequency |
50Hz ± 0.5Hz |
| capacity |
>10KVA |
| inner resistance |
380V:1 Ω ,220V:0.5 Ω |
MAX.CAPACITY OF PHOTOGRAY
| Focus of X-ray tube |
photograpy mA |
Max.photograpy KV |
Max.allowable expose time |
| small focus |
25mA |
100 |
2s |
| big focus |
50 mA |
100 |
6.3s |
| 100 mA |
85 |
3.2s |
| 125 mA |
80 |
1.25s |
TECHNICAL PARAMETER
| ITEM |
CONTENT |
INDEX |
| Max. Dc output voltage:100KVp |
| Max. Dc output current:150mA |
| Roentgenoscopy |
voltage |
50~90KV p |
| current |
0.5~5mA |
| Photograpy |
voltage |
50~100KV p |
| current |
small focus 25mA and big focus 50 、 100 、 150mA four grades together |
| spot film |
100mA(fixed) |
| time |
0.04~6.3s,24 grades together |
| High-Voltage generator |
capacity |
9KW |
| X-Ray tube |
model |
XD4~2.9/100 |
| focus |
small focus 1.8mm big focus4.3mm |
| Examining |
rotary angle |
+90 o ~ 0 o ~ -5 o |
| specifi-cation of spot film(stomach and intestines photograpy) |
128X179mm(5”X7”) |
| 205X254mm(8”X10”) |
| 254X305mm(10”X12”) |
| 256X366mm(14”X14”) |
Note:1.As to the products of the technical index with ※,the users can put forward their requirements whe